Other information:
Initialization
WARNING:
Keep objects and body parts clear of the glass panel when
carrying out the initialization procedure. During the initialization
procedure, the glass panel closes with high force and cannot detect
objects in its path. Failure to follow this instruction may result in
serious personal injury.
NOTE:
A new roof opening panel motor must be initialized after
i..
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Remove the instrument panel upper section.
Refer to: Instrument Panel Upper Section (501-12 Instrument Panel and Console, Removal and Installation).
Detach the wiring harness retainer, remove the nuts and the instrument panel upper brace.
Torque:
133 lb.in (15 Nm)
..