Ford Fusion: Automatic Transmission - 6-Speed Automatic Transmission – 6F35 / Transmission Fluid Exchange. General Procedures
Materials
Name |
Specification |
Motorcraft® MERCON® LV Automatic Transmission Fluid XT-10-QLVC |
WSS-M2C938-A MERCON® LV,
|
Connect
-
With the vehicle in NEUTRAL, position it on a hoist.
Refer to: Jacking and Lifting - Overview (100-02 Jacking and Lifting, Description and Operation).
Refer to: Jacking and Lifting - Overview (100-02 Jacking and Lifting, Description and Operation).
Refer to: Jacking and Lifting - Overview (100-02 Jacking and Lifting, Description and Operation).
-
Use the Fluid Exchanger to change the fluid.
Material: Motorcraft® MERCON® LV Automatic Transmission Fluid
/ XT-10-QLVC
(WSS-M2C938-A)
(MERCON® LV, )
-
Connect the Fluid Exchanger to the transmission
fluid cooler tube after the transmission fluid cooler on the return
tube. This will help remove any foreign material trapped in the
transmission fluid coolers.
-
Perform the transmission fluid exchange using the Fluid Exchanger. Follow the manufacturer's instructions included with the machine.
-
Once the transmission fluid exchange is completed, disconnect the Fluid Exchanger. Reconnect any disconnected transmission fluid cooler tubes.
-
Check the transmission fluid level.
Refer to: Transmission Fluid Level Check (307-01A Automatic Transmission - 6-Speed Automatic Transmission – 6F35, General Procedures).
Refer to: Transmission Fluid Level Check (307-01A Automatic Transmission - 6-Speed Automatic Transmission – 6F35, General Procedures).
Materials
Name
Specification
Motorcraft® MERCON® LV Automatic Transmission FluidXT-10-QLVC
WSS-M2C938-AMERCON® LV,
Draining
With the vehicle in NEUTRAL, position it on a hoist...
Materials
Name
Specification
Motorcraft® MERCON® LV Automatic Transmission FluidXT-10-QLVC
WSS-M2C938-AMERCON® LV,
Check
Connect the diagnostic scan tool to the vehicle...
Other information:
Check
NOTE:
Refer to the appropriate Section 303-01 for the specification.
Measure the piston diameter 90 degrees from the piston
pin and 41 mm (1.61 in) down from the top of the piston at the point
indicated.
..
Removal
WARNING:
Turn the ignition OFF and wait one minute to deplete
the backup power supply. Ignition must remain OFF until repair is
complete. Failure to follow this instruction may result in serious
personal injury or death in the event of an accidental deployment.
If a SRS fault is present, continue to Step 2. Otherwise, turn the ignition OFF, wait at least one minute a..