Special Tool(s) /
General Equipment
310-250Disconnect Tool, Fuel LineTKIT-2012A-FLTKIT-2012A-ROW
Disconnect
NOTICE:
When reusing liquid or vapor tube connectors, make sure to
use compressed air to remove any foreign material from the connector
retaining clip area before separating from the tube or damage to the
tube or connector retaining clip can occur...
Other information:
General Specifications
Item
Specification
Normal engine cranking speed (Average)
200-300 Revolutions Per Minute (RPM)
Starting circuit maximum voltage drop (Engine at normal operating temperature) (Average)
0.5 volt
Starter motor maximum load current draw
900 amps
Starter motor no-load current draw (Avera..
Special Tool(s) /
General Equipment
Refrigerant Identification Equipment
Activation
NOTE:
Use Refrigerant Identification Equipment to identify
gas samples taken directly from the refrigeration system or storage
containers prior to recovering or charging the refrigerant system.
NOTE:
Use Refrigerant Identification Equipment that conforms to SAE J2912 standard for R-1234yf..