Ford Fusion Manuals

Ford Fusion: Climate Control System - General Information / Electronic Leak Detection - Vehicles With: R1234YF Refrigerant. General Procedures

Ford Fusion 2013–2020 Service Manual / Electrical / Climate Control System / Climate Control System - General Information / Electronic Leak Detection - Vehicles With: R1234YF Refrigerant. General Procedures

Special Tool(s) / General Equipment

Electronic Leak Detector

Inspection

  1. NOTE: Use a Rotunda-approved Electronic Leak Detector for R-1234yf refrigerant SAE Certified to J2913.

    NOTE: Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is contaminated with refrigerant gas, the leak detector indicates this gas all the time. Odors from other chemicals such as antifreeze, disc brake cleaner or other cleaning solvents can cause the same problem. Using a fan to ventilate the area to be tested before proceeding with the leak detection procedure is helpful in removing small traces of contamination from the air, but the fan should be turned off during actual testing.

    NOTE: If the surrounding air is contaminated with refrigerant gas, the leak detector indicates this gas all the time. Odors from other chemicals such as antifreeze, disc brake cleaner or other cleaning solvents can cause the same problem.

    NOTE: R-1234yf, if present, is heavier than air, and tends to move down from the source of the leak. It is possible that a leak may not be detected if the leak detector tip is held above the leaking fitting, line or component. Always be sure to thoroughly leak test below, above and around the fitting, line or component for the presence of R-1234yf.

    Leak check the service ports. Remove caps and blow air over the service ports to remove trapped refrigerant before leak testing ports.
    • 339-D440A Techno Tool SAE Certified Refrigerant Leak Detector.
      Use the General Equipment: Electronic Leak Detector
    • 023‐LD7 Robinair Premium Refrigerant Leak Detector
      Use the General Equipment: Electronic Leak Detector
  1. NOTE: The system pressure should be 413-551 kPa (60 - 80 psi) at 24° C (75.2° F) with the engine off and cool. The pressure reading may be higher if the engine is hot.

    Leak test the refrigerant system. Follow the instructions included with the Electronic Leak Detector for handling and operation techniques.

    Condenser Core Leak Check - Vehicles With: R1234YF Refrigerant. General Procedures

    Special Tool(s) / General Equipment Air Conditioning Service Unit Air Conditioning Adaptor Kit Inspection Recover the refrigerant...

    Evaporator Core Leak Check - Vehicles With: R1234YF Refrigerant. General Procedures

    Special Tool(s) / General Equipment Air Conditioning Service Unit Air Conditioning Adaptor Kit Inspection Recover the refrigerant...

    Other information:

    Ford Fusion 2013–2020 Service Manual: Lane Keeping System. Diagnosis and Testing


    DTC Chart(s) Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods (100-00 General Information, Description and Operation).   IPMA DTC Chart   DTC Description Action B11C7:46 High Beam Sensor: Calibration/Parameter Memory Failure DIAGN..

    Ford Fusion 2013–2020 Service Manual: Message Center - Overview. Description and Operation


    Overview The message center is an integral part of the IPC that receives and acts upon much of the same information that is input and used to operate the IPC (gauges, informational indicators, and warning indicators). The message center uses both hardwired and network-based inputs to receive information. The message center functionality is controlled through the message center switch (part of..

    Categories

    Direction Indicators. Interior Lamps

    Direction Indicators

    Ford Fusion. Direction Indicators. Interior Lamps

    Push the lever up or down to use the direction indicators.

    read more

    Copyright © 2025 www.fofusion2.com